heat pump, wells for geothermal heating and peristaltic pumps.

Peristaltic pump for construction of wells for geothermal energy with heat pump.

heat pump and peristaltic pumpA major european company, specialized in foundation works, in recent years, has introduced a division that deals with installation of geothermal plants with heat pump.These plants provide the realization of the wells drilled in the ground for the installation of geothermal piping and sensors. These wells are typically low-depth, up to a maximum of 150 meters and small diameter. Inside of the wells are inserted the vertical geothermal sensors consisting in polyethylene pipes with plant connections. Subsequently, the wells are isolated by filling with a specific material that is placed between the pipes and the bore of the well. The filling material, in addition to the thermal conductivity must also ensure a low solubility, to avoid interaction with the groundwater and must also guarantee a good elasticity to avoid collapsing of the soil, the filling material most commonly used is a grout, cement-based and bentonite, which serves perfectly to this function and is widely used in the engineering of specialized foundations. The mixture looks like a thick mud but rather fluid. The operation of isolation of the well is of fundamental importance for the purposes of the maximum thermal output, and must be made perfectly before connecting the geothermal wells and the heat pump plant. To effectuate the preparation and transfer of the bentonite mixture, two pumps, Hose Carrier HCP 6.5 have been purchased. The pumps are realized with compact dimensions and equipped with a mechanical variator to adjust the flow rate easily. The customer placead the pump on custom skid complete with electrical panel and protections so is possible control the pump, directly on board of a vehicle, or on construction yard. The two pumps operate by 2011 with an annual consumption of 4 tubular membranes. Which makes us assume that should work with particularly intense rhythms.

For more information on : Hose Carrier HCP 6.5

Peristaltic Pumps Hose Carrier for percolate (Leachate) aspiration

Leachate suction pump

peristaltic pump for leachateAn important group engaged in the environmental sector, manages a landfill of solid non-hazardous, leachate or percolate is one of products deriving from the accumulation. The leachate is generated in a natural way by the crossing of rainfall through the layer of waste present in landfills, the result is a fluid from the characteristics extremely polluting, and therefore must be picked up and treated on site by means of a appropriate purification process .

There are different systems to suck the percolate, some bore hole submersible pumps inserted in appropriate wells, other systems provide surface self-priming pumps  able to aspirate the fluid from the surface. The landfill was designed considering not to apply submersible pumps  type to avoid  maintenance substantial costs in failure   or malfunction. In previous experiences it is noticed that whenever it is necessary the maintenance of the submersed pump, it is necessary to remove virtually all installation, raising the pump through its pipe by expensive equipment and specialized personnel.

Leachate has a chemical aggressiveness of a certain importance,variable over time, and is able to put out of order the submersible pumps in short times. In principle are also used for the percolate, pumps designed for clean water or with small modifications of adaptation to percolate , but that, as it was found, do not guarantee duration in time acceptable.

Maintenance and replacement operations are very expensive because they require disassembly total line in the well, as well as the use of suitable equipment such as cranes and lorries, transfers and interventions in specialised workshops with technical staff at high cost. The plant of the landfill was consequently designed for the use of surface pumps, through the realisation of a crowning achievement of picking stations with negative leaf not deep over eight meters.

Various Peristaltic Pumps Hose Carrier HCP 5.0 have been installed to suck the leachate directly from the surface. The high vacuum produced by the pump and full compatibility of the machine to the chemical aggression in addition to the total insensitivity to the dry running, has allowed the achievement full both of the objectives of the operational character an economic nature . The cost of maintenance of the individual pumping stations provides only the replacement of the tubular membrane (once every 2 years). The replacement takes place in the site, quickly, with no the additional costs  for the operation (an hour) with internal staff at the management company.

The on-site maintenance occurs without remove piping and tubing but acting only and exclusively on the pump on the surface, away from the contaminant. The management company has spoken in a very positive manner on the solution adopted, and proposes the purchase of new units for extensions and other future projects.

More information on the Pump Hose Carrier HCP 5.0